The NBC-77 SOF 40mm gas mask filter canister is a highly reliable and durable filtration system designed to protect against a wide range of harmful and toxic substances, including CBRN (Chemical, Biological, Radiological, and Nuclear) agents. Here are the key features of the NBC-77 SOF filter:
- Compatibility: The filter canister is compatible with standard 40mm NATO threaded respirators, which are widely used and readily available in the market. This ensures easy integration with various full-face masks, mouthpiece assemblies, or powered air-purifying respirators (PAPRs).
- Long Shelf Life: With a shelf life of 20 years, the NBC-77 SOF filter offers significant cost savings by eliminating the need for frequent filter replacements. This long-term durability makes it an economical choice for military personnel, CBRN specialists, and special operations forces.
- Comprehensive Protection: The filter is designed to provide protection against all known CBRN agents, including radioactive iodine. It is rated for A2B2E2K2HgSXP3 D R, indicating its effectiveness against a wide spectrum of chemical, biological, and radiological hazards.
- Robust Construction: The filter components are made of hard plastic, resulting in a robust and durable product that can withstand shock and impact damage during operational use. This ensures reliable performance in demanding environments and enhances user safety.
- Certifications: The NBC-77 SOF filter is certified by European agencies and bears the “CE” symbol, indicating compliance with relevant safety and performance standards. It meets the requirements of EN 14387:2004 + A1:2008, ensuring its efficacy and reliability in filtering hazardous substances.
Overall, the NBC-77 SOF 40mm gas mask filter is a trusted and proven filtration solution used by military and specialized personnel worldwide. Its compatibility, long shelf life, comprehensive protection, robust construction, and certifications make it an essential component of personal protective equipment for defense, emergency response, and hazardous material handling applications.
TECHNICAL DATA | BREATHING RESISTANCE IN PA BREATHING RESISTANCE IN PA | ||
---|---|---|---|
Diameter | 110 mm | @ flow rate 30l/min. EN 1) NBC-77 SOF 260 <140 | @ flow rate 95l/min. EN 1) NBC-77 SOF 980 <600 |
Height | 85 mm | ||
Weight | 335 g ±5% | ||
Storage time | 20 years (factory sealed) |
TYPE AND CLASS PARTICLE FILTER EFFICIENCY @ FLOW RATE 95L/M | PARTICLE FILTER EFFICIENCY @ FLOW RATE 95L/M | |||
---|---|---|---|---|
A2 – organic gases and vapors | SX – CG, CK, PS | Sodium Chloride NaCl (S) Paraffin oil (L) | EN 99.95 99.95 | NBC-77 SOF >99.999 >99.999 |
B2 – inorganic gases and vapors | P3 – particles | |||
E2 – acid gases and vapors | D- dust | |||
K2 – ammonia and amines | R- reusable | |||
Hg – mercury vapors | REACTOR – radioactive iodine |
Note:
1) Standard EN 14387+A1
2) The filter was tested on dolomite dust clogging
3) Radioactive iodine and its organic compound – methyliodide¹³¹ acc. to standard DIN 58621
NBC-77 SOF GAS MASK FILTER APPLICATION:
The filter canister in connection with a suitable respirator or PAPR provides protection against solid and liquid particles, pepper spray (OC), smoke-producing substances, radioactive particles, bacteria and rickettsia, fungi, toxins, viruses, riot control agents (lachrymators, sternutators, vomiting agents), blister agents (vesicants), choking agents, blood agents, nerve agents, incapacitants, herbicides, pesticides, and TIC, such as bromoacetone, CS, CR, CN, CNC, CNS, CA substances, organic compounds of arsenic – diphenyldichlorarsine – CLARK I (DA), diphenylcyanoarsine – CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulphur mustard gas (HD), T-mustard gas, Q-mustard gas, nitrogen mustard gases (HN1, HN2, HN3), lewisite (L), mixed mustard gas (H-L), phosgene oxime (CX), phosgene (CG), diphosgene(DP), chloropicrin (PS), hydrogen cyanide (AC), cyanogen chloride (CK), arsine (SA), G-agents: sarin (GB), cyclosarin (GF), soman (GD), tabun (GA), IVA (GV), V-agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: fumes of organic or inorganic acids, hydroxides, organic solvents with a boiling point above 65° C, ammonia, amines, inorganic and acid gases, agricultural chemical combustion gases, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, chloroacetic acid, aldehydes, mixtures of inorganic acids, and organic substances, mercury vapors, radioactive iodine, organic compounds of iodine (Iodomethane, 129, 131), radioactive particles, etc.
TESTING GAS | CONCENTRATION OF TESTING GAS | BREAKTHROUGH TIME IN MINUTES EN | NBC-77 SOF | DAC IN GRAMS NBC-77 SOF | |||
---|---|---|---|---|---|---|---|
PPM | MG/I | ||||||
A2 | Cyclohexane | C₆H₁₂ | 5000 | 17.5 | 35 | 39 | 20.475 |
B2 | Chlorine | Cl₂ | 5000 | 15 | 20 | 45 | 20.250 |
Hydrogen Sulphide | H₂S | 5000 | 7.1 | 40 | >80 | >17.400 | |
Hydrogen Cyanide | HCN | 5000 | 5.6 | 25 | 50 | 8.400 | |
E2 | Sulphur Dioxide | SO₂ | 5000 | 13.3 | 20 | 25 | 9.975 |
K2 | Ammonia | NH₃ | 5000 | 3.5 | 40 | 50 | 5.250 |
Hg | Mercury | Hg | —– | 13 mg/m³ | 100 hours | >170 hours | >3.900 |
SX | Cyanogen chloride | CICN | 2500 | 6.28 | 20 | 25 | 4.710 |
Chloropicrin | CCI₃NO₃ | 5000 | 33.55 | 20 | 44 | 44.286 | |
Phosgene | COCl₃ | 5000 | 20.24 | 20 | >77 | >47.058 | |
REACTOR | Methyloidide₁₃₁ | CH₃I | – | – | 2 hours | >2 hours | – |
GAS MASK FILTER LIFETIME:
Breakthrough time of a gas mask filter is tested according to EN 14387+A1 at humidity 70% and flow rate 30 l/min, which is equivalent to the volume of air per minute used by an average person carrying out medium heavy work. The approximate lifetime (usage time) of a filter may, under normal conditions, calculated by comparing the concentration at the workplace and the minimum Dynamic Adsorption Capacity (DAC) for the filter.
GAS MASK FILTER STORAGE AND MAINTENANCE:
Each NBC-77 SOF gas mask filter is sealed in a plastic bag by the manufacturer. Store the filters unopened in a clean place at even temperature, most appropriate at -5 to +30°C and relative humidity below 80%. Sealed filters tolerate also conditions of -30 to +50°C and RH below 95%. The storage period (month and year) for filters is marked on the filter label. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.
GAS MASK FILTER DISPOSAL:
After use, gas mask filters are considered special refuse. Make sure that they are disposed of according to the filtered substance (gases or particles) in accordance with current waste treatment regulations. If the product is to be disposed of, it should be dismantled from the respirator and disposed of as solid waste. Please see local authority regulations for disposal advice and locations.
Reviews
There are no reviews yet.